Recent Discussions
ADK 18362.1 DISM Fails Offline Install for kb4497936+kb4505057 for WinRE.wim
DISM fails to install 14/May/2019 LCU on Winre.wim KB4497936 (Released 11/5/2019 with KB4500109) KB4505057 (Released 20/5/2019) The image is unmounted, however DISM continues to install package, using host system registry, not mounted image registry. 2019-05-15 22:26:30, Info DISM DISM.EXE: <----- Starting Dism.exe session -----> 2019-05-15 22:26:30, Info DISM DISM.EXE: 2019-05-15 22:26:30, Info DISM DISM.EXE: Host machine information: OS Version=10.0.18362, Running architecture=amd64, Number of processors=8 2019-05-15 22:26:30, Info DISM DISM.EXE: Dism.exe version: 10.0.18362.1 2019-05-15 22:26:30, Info DISM DISM.EXE: Executing command line: "D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\dism.exe" /Unmount-Image /MountDir:E:\WinROG\mount\RE /DISCARD 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Getting the collection of providers from a local provider store type. - CDISMProviderStore::GetProviderCollection 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Connecting to the provider located at D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\FolderProvider.dll. - CDISMProviderStore::Internal_LoadProvider 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Connecting to the provider located at D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\SiloedPackageProvider.dll. - CDISMProviderStore::Internal_LoadProvider 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Connecting to the provider located at D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\FfuProvider.dll. - CDISMProviderStore::Internal_LoadProvider 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Connecting to the provider located at D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\WimProvider.dll. - CDISMProviderStore::Internal_LoadProvider 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Connecting to the provider located at D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\VHDProvider.dll. - CDISMProviderStore::Internal_LoadProvider 2019-05-15 22:26:30, Info DISM DISM Provider Store: PID=2660 TID=3056 Connecting to the provider located at D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\ImagingProvider.dll. - CDISMProviderStore::Internal_LoadProvider 2019-05-15 22:26:30, Warning DISM DISM Provider Store: PID=2660 TID=3056 Failed to load the provider: D:\Windows Kits\10\Assessment and Deployment Kit\Deployment Tools\AMD64\DISM\MetaDeployProvider.dll. - CDISMProviderStore::Internal_GetProvider(hr:0x8007007e) 2019-05-15 22:26:30, Info DISM DISM.EXE: Got the collection of providers. Now enumerating them to build the command table. 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: DISM Log Provider 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: FolderManager 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: SiloedPackageManager 2019-05-15 22:26:30, Info DISM DISM.EXE: Succesfully registered commands for the provider: SiloedPackageManager. 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: FfuManager 2019-05-15 22:26:30, Info DISM DISM.EXE: Succesfully registered commands for the provider: FfuManager. 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: WimManager 2019-05-15 22:26:30, Info DISM DISM.EXE: Succesfully registered commands for the provider: WimManager. 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: VHDManager 2019-05-15 22:26:30, Info DISM DISM.EXE: Attempting to add the commands from provider: GenericImagingManager 2019-05-15 22:26:30, Info DISM DISM.EXE: Succesfully registered commands for the provider: GenericImagingManager. 2019-05-15 22:26:30, Info DISM DISM FFU Provider: PID=2660 TID=3056 [E:\WinROG\mount\RE] is not recognized by the DISM FFU provider. - CFfuImage::Initialize 2019-05-15 22:26:30, Info DISM DISM Imaging Provider: PID=2660 TID=3056 The provider FfuManager does not support CreateDismImage on E:\WinROG\mount\RE - CGenericImagingManager::CreateDismImage 2019-05-15 22:26:30, Info DISM DISM VHD Provider: PID=2660 TID=3056 [E:\WinROG\mount\RE] is not recognized by the DISM VHD provider. - CVhdImage::Initialize 2019-05-15 22:26:30, Info DISM DISM Imaging Provider: PID=2660 TID=3056 The provider VHDManager does not support CreateDismImage on E:\WinROG\mount\RE - CGenericImagingManager::CreateDismImage [2660] ImageUnmarshallHandle: Reconstituting wim at E:\WinROG\CustOEM-DaRT-RE-G751.wim. [2660] ImageUnmarshallHandle: Reconstituting wim at E:\WinROG\CustOEM-DaRT-RE-G751.wim. [2660] ImageUnmarshallHandle: Reconstituting wim at E:\WinROG\CustOEM-DaRT-RE-G751.wim. [11720] Received unmount request for image with guid e5043866-3c22-45c8-be93-1f56cf9ce0b4. [11720] Unmount for image at E:\WinROG\mount\RE complete. [2660] [0x8007000e] StateStoreGetMountedImageWimbootEntries:(1285): Not enough memory resources are available to complete this operation. [2660] Encountered file with excess reparse data. Id 0x00050000000236ad [2660] Encountered file with excess reparse data. Id 0x0005000000023712 [2660] Encountered file with excess reparse data. Id 0x00050000000237b1 [2660] Encountered file with excess reparse data. Id 0x00050000000237b2Solved10KViews0likes7CommentsSigning kernel driver fails with Cab Signature validation failed with error: 0x80090008
As of 14.09.2021 I am getting error when submitting drivers for signing. When I submit the CAB file, I get Cab Signature validation failed with error: 0x80090008. What causes the issue is a simple parameter of signtool.exe when I sign the CAB file. Obviously, Microsoft have changed the requirements for what type of CAB signing they accept. Till yesterday, my signtool.exe options were "/a /tr http://timestapprovider/ /td sha256 .. etc" After I got the error I started reading I found out I'm missing one more parameter : "/fd sha256" So, it should be like : "/a /fd sha256 /tr http://timestampprovider/ /td sha256 ... etc" To be honest I don't know how I have missed the change, but now it works. Hope this helps. Cheers, Daniel4.6KViews0likes4CommentsHLK-Testing: How to set "QueryValidationDriverFolder" parameter for HLK Test named "ApiValidator"
When starting the HLK-Test named "ApiValidator" test parameter settings are not offered to me. The test therefore fails because QueryValidationDriverFolder parameter string is empty. When I export the Test-Run and modify the parameter in the exported file run.cmd to indicate the correct folder, the test is successful in the exported TestRun, but when I trigger the test via the HLK-Studio it again fails. WHERE am I supposed to set this parameter so it is used when running via HLK-Studio? Thanks in advance, Erich Smutny1.2KViews0likes2CommentsDriver Signing for pre-Windows 2016 questions
I have some questions about what the recommendations are for generating a signed driver for Windows 2016 and earlier. I set up the HCK test server (2008 R2) and test system(2012 R2), installed my driver, ran the appropriate tests, and generated an HCKX. I do NOT have access to my EV Certificate on the HCK test server. I generated an unsigned .hckx file, and am trying to use the HLK Studio (which DOES have access to our EV Certificate) to sign it. Ideally, I'd like to end up with a driver that runs on Windows 2008 R2 (x64) through Windows 2022. We've run the HLK tests against Windows 2019 successfully, and I am able to submit that to the Hardware Dev Center and get a signed driver that works on 2016, 2019, and 2022. I was attempting to use the "merge" capabilities in the HLK Studio to bring in the .hckx file that we created on the HCK controller system. To do this, I created a new project and chose "Connect", and loaded the previous .hlkx file. Then I chose "merge" and added the .hckx file. I cleared the Drivers Folder that was pointing to my user TEMP directory, and added a single Drivers folder that contains the driver that we tested on both systems (2012 R2 and 2019). The Driver Properties lists both "Windows Server v10.0 17763" and "Windows Server v6.3" - I highlighted both of those, and added the English locale. Then I added a Symbols folder. I signed the resulting .hlkx file with our EV Certificate and uploaded it for signing at the HW Dev Center. The resulting download contains a signed copy of the driver, but the Microsoft signature is SHA256 (which I don't believe will work on 2012 R2). I tried installing it on a 2012 R2 system - won't boot. Any idea what I need to do differently to get this to work? Thanks! Ernie Coskrey1.1KViews0likes1CommentHow can I get the HCK?
Is there a location where the Windows Hardware Certification Kit v8.1 can be downloaded? The DevCenter now only appears to have HLK available. I believe I need the HCK in order to get drivers signed that will work with Windows Server 2012 R2 and earlier, correct?1KViews0likes1CommentGetting a PC certified for Windows
Hi, I am looking for guidance for how to get a Mini PC 'certified for Windows'. I think I need to carry out the process outlined https://docs.microsoft.com/en-us/windows-hardware/design/compatibility/ but I have some questions before I start. The PC is a custom design, has been in production for a number of years and the latest generation runs Win10 and Win11. We would like to be able to use 'Windows Certified' logo or reference in specifications. We can go through the process in the link above but does the company need to be a Microsoft Partner? Some simple questions but can't find someone within Microsoft that can answer. HP, Dell, etc. have done it but we are just a small firm in comparison and don't have high level contacts within Microsoft, hence this post. If someone knows the process or suggestions on where to look I would be most grateful. Thanks in advance. David790Views0likes1CommentCordial request to indicate the best application for Scanning Double Files.
Hello very warmly everyone on the Microsoft TechNet Community forum. I would like to ask you very warmly for your support. From the depths of my heart, I am asking you very warmly for your support. Please help. I need to scan the hard drive because I have double files, maybe triple too. From the depths of my heart, I am asking you very warmly for your support. Please send me the best application that has the ability to search the entire area of the Hard Drive double saved files. From the depths of my heart I turn to you so that this application can also search archives saved in zip format. From the depths of my heart, I ask that this application be able to scan the connected OneDrive Cloud, including zip files.759Views0likes1Comment
Events
Recent Blogs
- Microsoft is pleased to announce that a refreshed HLK for Windows 11, version 24H2 and Windows Server 2025 is available starting July 8, 2025. This release of the HLK contains only infrastructure c...Jul 08, 2025114Views0likes0Comments
- Microsoft is pleased to announce that a refreshed HLK for Windows 11, version 24H2 and Windows Server 2025 is available starting July 8, 2025. This release of the HLK contains only infrastructure c...Jul 08, 2025121Views0likes0Comments