HLK Refresh Release for Windows 11 HLK 24H2 and Windows Server 2025
Published Sep 19 2024 04:45 PM 2,919 Views
Copper Contributor

Microsoft is pleased to share that we will release a refreshed HLK for Windows 11 24H2 and Windows Server 2025 to in October.  

This release of the HLK will contain fixes for test Errata which will help keep the overall test quality high while helping reduce triage time for known test issues. The refreshed version of the HLK will replace the RTM version that is available on the HLK download sitePartners can submit to WHCP using either the RTM version of the HLK for Windows 11, version 24H2 and Windows Server 2025 or the refreshed HLK so long as passing results can be obtained (waivers acceptable).

 

Errata that are fixed in the refreshed version are expected to be expired 90 days after the release of the refreshed HLK. As we transition into this servicing model, which maintains overall test quality and reduces dependency on errata, we acknowledge that the refreshed HLK may not address all scenarios. If any errata remain relevant after using the refreshed HLK, please contact CSS for assistance. For more details, please review the Frequently Asked Questions.

 

Frequently Asked Questions

  • What HLK version is being refreshed?
    • The HLK released in May 2024 to support certifying drivers for Windows 11, version 24H2 and Windows Server 2025. For the following FAQ’s, the May 2024 release will be referenced to as RTM HLK and the upcoming release in October will be referenced as Refresh HLK.
  • How can I tell what version of the HLK I have?
    • The distinction between RTM HLK and Refreshed HLK will be in the last digits of the HLK studio version, 10.1.26100.X
      • The RTM HLK Studio version is 10.1.26100.1
      • The Refresh HLK Studio version is 10.1.26100.X

The HLK Studio version information can be located by clicking ‘About’ in the upper right corner of studio

 

Cymoki_0-1726789260015.png

 

Notes

      • Ensure your current HLK projects are finished before attempting to use the same system for the HLK Refresh.
      • The Refreshed HLK cannot be installed on a system that already has the RTM HLK, this goes for both Controller and Client. It is highly recommended to start with a clean install of the OS for both.
  • How can I tell if the Errata I use was fixed in the Refreshed HLK?
    • The list of Errata fixed is available below
  • What do I do if the Errata I use doesn’t appear to be fixed in the Refreshed HLK?
    • If the Errata is not on the fixed list the waiver can be used on both the RTM HLK as well as the Refreshed HLK
  • How should I address a test that was passing on the RTM HLK but now failing on the refreshed HLK?
  • Going forward, will Microsoft be updating the HLK regularly?
    • Yes, Microsoft is transitioning into this servicing model for the HLK, which maintains overall test quality and reduces dependency on errata.
  • How often are these refresh releases expected?
    • Current plan is to evaluate releasing a refreshed HLK each quarter.
  • Does this update apply to client and server?
    • Yes
  • Can results from an RTM test run and a Refreshed test run be merged and used for submission?
    • No, submission must be completed with either the RTM or Refreshed HLK.
  • Will the refreshed HLK continue to support merged packages for multiple-OS submissions?
    • Yes
  • Is the VHLK also going to be updated?
    • Yes

Errata Fixed in the October 24’ Refresh

 

ID Title Job/Task Failing
91345 [HLK Errata] AudioLogo (system) enforces channel count on default mode System Audio - Audio Logo Test
127433 [Auto-triage] New binary with endpoint stabilization delay Audio Codec - Lullaby Test - Certification - Desktop
161095 [HLK Errata]: Voice Clarity Driver Timestamp Test requires small mic spk stream drift Voice Clarity HLK Test Driver Timestamp
163288 [HLK Errata] Validation of UVC MJPG Translation Opt-in always fails for UVC IR Camera Camera Driver System Test - Validation of UVC MJPG Translation Opt-in
163289 [HLK Errata] Camera Driver Registration Test IMFSampleAllocator check fails on Platform DMFT Camera Driver Registration, Metadata, and Dependency System
164528 [HLK Errata] DF - PNP tests failure with Failed to open the EDT device (device specific) Multiple
164532 [HLK Errata] Driver Isolation DV failures for serial.sys accessing SERIALCOMM registry key. DV - EnumerateEvents
164702 [HLK Errata] Driver Isolation DV failures for wudfrd.sys accessing SERIALCOMM registry key. DV - EnumerateEvents
167195 [HLK Errata] Camera Driver Registration Test IMFSampleAllocator check fails on Platform DMFT Camera Driver Registration, Metadata, and Dependency System
167196 [HLK Errata] [Camera Driver Controls System Test - Framerate Throttle - Verify Mode Switching] - Does not account for Step Sizes Camera Driver Controls System Test - Framerate Throttle - Verify Mode Switching
167197 [HLK Errata] Sensor Camera Profiles - Photo Sequence with MEP Camera fails Sensor Camera Driver Controls System Test - CAMERA_PROFILES - Photo Sequence
167453 [HLK Errata] Media Capture TestFrameExposureControlWithCapture uses wrong Table Entry TestFrameExposureControlWithCapture
167494 [HLK Errata] Camera Driver Controls System Test - VFR - Verify correct Pin fails for MEP devices Camera Driver Controls System Test - VFR - Verify correct Pin fails for MEP devices
167738 [HLK Errata] Camera Driver System Test - MediaCapture - TestInfraredTorchControlMetadata fails for filtered Legacy Profile Camera Driver System Test - MediaCapture - TestInfraredTorchControlMetadata
167884 [HLK Errata] Camera Driver System Test - MediaCapture - ValidateExposureCompensationValues fails due to IR camera Camera Driver System Test - MediaCapture - ValidateExposureCompensationValues
168217 Human Presence Proximity Test Failing on Non Human Presence based Proximity Sensors Human Presence capable Proximity Sensor Enumeration Property Verification Test
168478 [HLK Errata] [NdisStudio] NDIS keyword validation tests are listed under incorrect feature, causing failures for devices not advertising NDIS [NdisStudio] NdisPoll keyword validation
[NdisStudio] NdisPoll keyword functional validation
168710 [HLK Errata] Display Capture Tests failing for Indirect Display devices Display capture tests
170424 [HLK Errata] Camera Driver System Test - MediaCapture - Digital Window Metadata fails for combined IR RGB Sensor Group Camera Driver System Test - MediaCapture - Digital Window Metadata
171184 [HLK Errata] [NdisStudio] OidRequestTest - OID_GEN_XMIT_OK and OID_GEN_RCV_OK Verification test fail when link speed is less than 1Gbps [NdisStudio] OidRequestTest - OID_GEN_XMIT_OK and OID_GEN_RCV_OK Verification
173553 [HLK Errata] Camera Driver Hardware Privacy Manual Test fails due to Kill Switch behavior Camera Driver Hardware Privacy Manual Test
173718 [HLK Errata] NDISTest 6.5 - [2 Machine] - PM_PowerStateTransition & PM_WolMagicPacket & PM_WolPattern test fail NDISTest 6.5 - [2 Machine] - PM_PowerStateTransition
NDISTest 6.5 - [2 Machine] - PM_WolMagicPacket
NDISTest 6.5 - [2 Machine] - PM_WolPattern
173736 [HLK Errata] Camera Driver Controls System Test - VIDEOSTABILIZATION - Iterate through possible settings while Preview fails with MEP due to Pin re-mapping Camera Driver Controls System Test - VIDEOSTABILIZATION - Iterate through possible settings while Preview
175039 [HLK Manual Errata]: NDIS test failed due to the certificate in HLK Studio is out of date [NdisStudio] OidRequestTest - OID_GEN_VENDOR_DRIVER_VERSION Verification
[NdisStudio] OidRequestTest - OID_GEN_VENDOR_ID Verification
[NdisStudio] OidRequestTest - OID_GEN_XMIT_OK and OID_GEN_RCV_OK Verification
[Network Adapter] Verification for network
177219 [HLK Errata] Camera Driver System Test - Mediacapture - TestEffectOptInCameraEnumeration does not check regkey value Camera Driver System Test - Mediacapture - TestEffectOptInCameraEnumeration
177825 [ERRATUM] KS Topology Test Fails Custom Audio Modes System Audio - KS Topology Test
179949 [HLK Errata] Camera Control Pin Verification Tests failing due to MEP Pin remapping Sensor Camera Driver Controls System Test - * - Verify correct Pin
181916 [HLK Errata] Driver Isolation DV failures for snxpsamd.sys accessing SERIALCOMM registry key. DV - EnumerateEvents
184662 [HLK Manual Errata]: A crash with exception code 0xC0000005 occurred when running InternalPanel - Common color profile problems test InternalPanel - Common color profile problems
188557 AutoTriage: HLK USB Secure Camera Controller Dual BDF Test - Compat test failure. USB Secure Camera Controller Dual BDF Test - Compat

 

Co-Authors
Version history
Last update:
‎Sep 19 2024 04:44 PM
Updated by: