Blog Post

Windows Hardware Certification
6 MIN READ

HLK February Refresh Release for Windows 11 Version 25H2 and Windows Server 2025

Cymoki's avatar
Cymoki
Icon for Microsoft rankMicrosoft
Feb 17, 2026

Microsoft is pleased to announce that a refreshed HLK for Windows 11, version 25H2 and Windows Server 2025 is available starting February 17, 2026. 

See below for detailed information on what’s new with this HLK refreshed version. The refreshed version of the HLK will replace the RTM version that is available on the HLK Download site. The VHLK version will be available in a week. Partners can submit to WHCP using either the RTM version of the HLK for Windows 11, version 25H2 and Windows Server 2025 or the refreshed HLK so long as passing results can be obtained (waivers acceptable). 

What's new with this refresh? 

We’ve introduced a small update to the HLK ARM64 Client setup experience by defaulting the emulation test setting to x86. This change aligns ARM64 client testing more closely with the existing AMD64 workflow, allowing partners to use a single, unified playlist for ARM64 testing, including both full and emulation scenarios. By reducing the need to manage multiple architecture specific playlists, we’re making it faster and easier for partners to stand up an ARM64 emulation test environment, minimize playlist configuration overhead, and focus on validating driver quality.  In the February refresh, partners can point to x86 as default emulation during automated script setup and enjoy the benefit of the single playlist deployment; in the following quarterly refresh, the default UI change will be available as well.

 

In addition, the refreshed kit includes a new check for unreferenced files. If the attached driver package includes one or more files that were not referenced by an .inf, a new warning will display at the end of packaging. The PackageWriter class in the Microsoft.Windows.Kits.Hardware.ObjectModel.Submission namespace has been updated to provide access to this new information from the HLK API. Please see Attention: HDC is changing the policy on signing unreferenced files in driver packages | Microsoft Community Hub for details. 

 

25H2 Playlist updates:  

The following tables describe the playlist changes included with this refresh. 

Removed tests: 

GUID 

TestName 

 

7bcca3c4-3853-4f22-8eb2-effa2feeba57 

Bluetooth - LE Audio VSAP (Broadcast) - [Render] Default, 32_1, 1 channel 

4a3813a2-b24c-4784-b932-f2aa1e559747 

Bluetooth - LE Audio VSAP (Broadcast) - [Render] Default, 32_1, 1 channel 

25a4e032-246f-491d-b246-5be7dd8abb3e 

Bluetooth - LE Audio VSAP (Broadcast) - [Render] Default, 32_2, 1 channel 

4981e0a5-3583-4c49-896f-8342c70d75dc 

Bluetooth - LE Audio VSAP (Broadcast) - [Render] Default, 32_2, 2 channels 

b88a8d7b-4e43-41c2-b8e6-e6cb63a1f431 

DXGI - Hybrid WDDM 3.0 

f4f5a8a2-91fe-4508-a75c-24fe46c2b1f3 

Display capture tests - Display Mode Change Performance 

b80af82b-6d0b-4ac5-b649-4c02c1242570 

DisplayMux Acpi block test 

d0aaac5c-7c4c-488c-8352-14c49bc2ac67 

NDISTest 6.0 - [1 Machine] - 1c_NdisRequestCov 

5d6ac688-70fd-4163-8313-ffa2922b2afd 

NDISTest 6.0 - [1 Machine] - 1c_WMICoverage 

5f53cf62-a767-4469-92e6-1bca087193fd 

NDISTest 6.0 - [2 Machine] - 2c_Priority 

16084044-7baf-48ca-abe8-ae68062bebef 

RepeatPublishWriteTag 

d7e5b99f-d655-484c-a4ed-6467976d7813 

RepeatTagReading 

0cc234e0-9513-48fd-8b5d-1ef9ce168941 

RepeatTagReadingLonghaul 

 

Added tests: 

GUID 

TestName 

Additional Information 

9d59f9d8-ca18-42db-8bc7-a50bf071af00 

Driver Attribute Test 

This test is being added to the playlist. It reports the version of the WDK used to build the driver package. This test does not currently cause any failures as it is reporting only. 

9f351400-f4fa-42b1-8c53-7affb526ee78 

 

GRFX Adapter - Unreleased Features Block 

Our new GRFX Adapter Unreleased Features Block Test will prevent graphics drivers from showing full support for unreleased features. Once a feature has been released, we will check that the system passes the corresponding HLK tests associated with the feature and remove it from the unreleased feature list. 

 

d3d5e718-9313-4de6-9b38-41facdfd6314 

 

Wlan Test - Connect to an enterprise network using MLO 

Adding missing test that supports existing WHCP requirements. 

 

26H1 Playlist (only) updates, no new HLK Kit:  

Removed tests: 

GUID 

Test Name 

b88a8d7b-4e43-41c2-b8e6-e6cb63a1f431 

DXGI - Hybrid WDDM 3.0 

16084044-7baf-48ca-abe8-ae68062bebef 

RepeatPublishWriteTag 

d7e5b99f-d655-484c-a4ed-6467976d7813 

RepeatTagReading 

0cc234e0-9513-48fd-8b5d-1ef9ce168941 

RepeatTagReadingLonghaul 

067dba2c-6ee8-48a8-bb23-11182608f64c 

 

BitLocker TPM + PIN + USB and Recovery Password Tests 

ce9e5b64-8903-4025-bccf-a99d65663cf8 

 

BitLocker TPM and Recovery Password Tests for NONAOAC devices with Legacy PCRs 

5aac52da-a57c-4a12-aaac-de878a62bb08 

 

BitLocker Tpm And Recovery Password tests for AOAC devices with PCR[7] 

8a4641a2-4fc6-4447-9d94-fdf402ca263c 

 

BitLocker Tpm And Recovery Password tests for AOAC devices with Legacy PCR's 

8c7a62bb-7f02-4a16-b37d-711cc9026e17 

 

BitLocker TPM and Recovery Password Tests for NONAOAC devices with PCR[7] 

 

Added tests: 

GUID 

Test Name 

Additional Information 

d3d5e718-9313-4de6-9b38-41facdfd6314 

 

Wlan Test - Connect to an enterprise network using MLO 

Adding missing test that supports existing WHCP requirements. 

067dba2c-6ee8-48a8-bb23-11182608f64c 

 

BitLocker TPM + PIN + USB and Recovery Password Tests 

Replacing existing BitLocker Tpm+PIN+ USB and Recovery Password tests.  

721864b7-a33e-4831-bfb3-7e04e67a6f87 

 

BitLocker Device Encryption Test 

 

New HLK test, doesn't raise WHCP bar as we use software APIs to determine hardware capability for DE. 

 

ba380fe0-7d56-432e-b504-56b73201d08a 

 

BitLocker TPM and Recovery Password Tests for AOAC devices 

Replacing BitLocker Tpm and Recovery password tests for AOAC devices with PCR[7] and  BitLocker Tpm and Recovery password tests for NONAOAC devices with Legacy PCRS. 

008d97d3-1535-4abe-b0c4-9663e5e12b1f 

 

BitLocker TPM and Recovery Password Tests for NONAOAC devices with Legacy PCRs 

Replacing BitLocker Tpm and Recovery password tests for NONAOAC devices with Legacy PCRS. 

e922e6ac-a3ca-4e7f-a4c6-4b3ce685ec4f 

 

BitLocker TPM and Recovery Password Tests for NONAOAC devices with PCR[7] 

Replacing  BitLocker Tpm and Recovery password tests for NONAOAC devices with PCR[7]. 

 

 

 

Troubleshooting and Known Issues:  

Issue: "Failed to open package. Could not open package: (hlkx filename)" when opening HLKX generated from this release on separate system. 

Submission packages from this release are generated in a new schema and a newer version of the HLK Studio is required to open it.   

Solution: Install/Update to a newer of HLK or HLK Studio 

Existing HLK Controller installations may be kept as is and do not need to be reinstalled as it is not supported to update just the HLK Studio on an existing HLK Controller instance. An HLK Studio only instance from the latest HLK may be installed on a separate system to open these HLKXes. 

 

Issue: Wi-Fi tests regressed due to removal of TestNetv2.0 dependencies. 

The TestNetv2.0 was removed from the HLK test infrastructure, causing some Wi-Ffi tests to regress due to not being able to invoke “testnetv2.0/ccrun.exe”. The list of affected tests can be found below 

  • Wi-Fi Direct Basic Discovery Tests – Functional 
  • Wi-Fi Direct Basic Pairing Tests – Functional 
  • Wi-Fi Direct Basic Reconnect Tests – Functional 
  • Wi-Fi Direct Legacy Pairing Tests – Functional 
  • Wi-Fi Direct Service Discovery Tests – Functional 
  • Wi-Fi Direct Service Pairing and Reconnect Tests – Functional 

 This issue will be fixed on a future refresh of the 25H2 Hardware Lab Kit 

 

Frequently Asked Questions 

  • What HLK version is being refreshed? 
    • The 25H2 RTM HLK is being refreshed, this HLK helps support certifying drivers for Windows 11, version 25H2 and Windows Server 2025. For the following FAQ’s, the 25H2 RTM release will be referenced to as RTM HLK and the upcoming release in February 2026 will be referenced as refresh HLK. 
  • How can I tell what version of the HLK I have? 
    • The distinction between RTM HLK and refreshed HLK will be in the last digits of the HLK studio version, 10.1.26100.X 
      • The RTM HLK Studio version is 10.1.26100.1 
      • The refresh HLK Studio version is 10.1.26100.X 

The HLK Studio version information can be located by clicking ‘About’ in the upper right corner of studio. 

  

  • How do I install the refreshed version of the HLK? 
    1. To install the refreshed version of the HLK, visit the HLK download page: Windows Hardware Lab Kit | Microsoft Learn 
    2. Download the refreshed HLK 
    3. Run HLKSetup.exe 

Notes 

    • Ensure your current HLK projects are finished before attempting to use the same system for the HLK refresh. 
    • The refreshed HLK cannot be installed on a system that already has the RTM HLK, this goes for both Controller and Client. It is highly recommended to start with a clean install of the OS for both. 

 

  • How should I address a test that was passing on the RTM HLK but now failing on the refreshed HLK? 
  • Going forward, will Microsoft be updating the HLK regularly? 
    • Yes, Microsoft is transitioning into this servicing model for the HLK, which maintains overall test quality and reduces dependency on errata. 
  • How often are the HLK refresh releases expected? 
    • Our current plan is to evaluate releasing a refreshed HLK each quarter.  
  • Does this update apply to client and server? 
    • Yes 
  • Can results from an RTM test run and a Refreshed test run be merged and used for submission? 
    • No, submission should be completed with either the RTM or refreshed HLK. 
  • Will the refreshed HLK continue to support merged packages for multiple-OS submissions? 
    • Yes 
  • Is the VHLK also going to be updated? 
    • Yes 

 

Updated Feb 20, 2026
Version 2.0
No CommentsBe the first to comment