Jul 19 2018 04:48 AM
My goal is to test the work of S2D.
v17709:
I configured RSS on 4 NICs - by 4 queue on each NIC.
VMM v1801 can not create Logical Switch , process permanently hung on 10%. When I canceled job I see new Switch without vNIC and with incorrect settings. This Switch can not be deleted neither in VMM, Hyper-V, Powershell, only if use registry.
v17713:
I configured RSS on 4 NICs - by 4 queue on each NIC. But NIC3 always not configured:
-----------------
BaseProcessor: [Group:Number] : 0:18
MaxProcessor: [Group:Number] : 0:24
MaxProcessors : 4
RssProcessorArray: [Group:Number/NUMA Distance] : 0:18/32767 0:20/32767 0:22/32767 0:24/32767
IndirectionTable: [Group:Number] :
-----------------
Profile : NUMAStatic
BaseProcessor: [Group:Number] : 0:24
MaxProcessor: [Group:Number] : 0:30
MaxProcessors : 4
RssProcessorArray: [Group:Number/NUMA Distance] : 0:24/32767 0:26/32767 0:28/32767 0:30/32767
IndirectionTable: [Group:Number] :
VMM v1801 can not create Logical Switch, error
Jul 19 2018 05:52 AM
VMM v1801 can create Logical Switch on clean installation of OS v17713