NetAdapterRSS, VMM LogicalSwitch & etc.

Copper Contributor

My goal  is to test the work of S2D.

v17709:

I configured RSS on 4 NICs - by 4 queue on each NIC.

VMM v1801 can not create Logical Switch , process permanently hung on 10%. When I canceled job I see new Switch without vNIC and with incorrect settings. This Switch can not be deleted neither in VMM, Hyper-V, Powershell, only if use registry.

v17713:

I configured RSS on 4 NICs - by 4 queue on each NIC. But NIC3 always not configured:

-----------------

BaseProcessor: [Group:Number]                   : 0:18
MaxProcessor: [Group:Number]                    : 0:24
MaxProcessors                                   : 4
RssProcessorArray: [Group:Number/NUMA Distance] : 0:18/32767  0:20/32767  0:22/32767  0:24/32767

IndirectionTable: [Group:Number]                :

-----------------

Profile                                         : NUMAStatic
BaseProcessor: [Group:Number]                   : 0:24
MaxProcessor: [Group:Number]                    : 0:30
MaxProcessors                                   : 4
RssProcessorArray: [Group:Number/NUMA Distance] : 0:24/32767  0:26/32767  0:28/32767  0:30/32767
IndirectionTable: [Group:Number]                :

 

VMM v1801 can not create Logical Switch, error 

Verb: [INVOKE], Method: [GetFinalResult], Resource: [http://schemas.microsoft.com/wbem/wsman/1/wmi/root/scvmm/AsyncTask?ID=1002]
Unknown error (0x80078005)
But Host is managed from VMM, I can change other settings.
 
1 Reply

VMM v1801 can create Logical Switch on clean installation of OS v17713