Symptom

 

Unable to create new flow rules for either inbound or outbound SR in FIM portal. This appears to be non-OS specific.

 

 

 

Cause

 

This is because of issue with MS14-080 cumulative security update for IE: December 9, 2014. From KB 3008923:

 

 

 

Known issues with this security update



    • Issue 1
      We are aware of some reports of functional issues on sites that use nested modal dialog boxes on Internet Explorer 11 that occur after you install this security update.
      To resolve this issue, install update 3025390. For more information, click the following article number to view the article in the Microsoft Knowledge Base:
      3025390

      Some web application modal dialog boxes don't work correctly in Internet Explorer 11 after you install update 3008923



Resolution

 

Install KB 3025390 as suggested by security update KB above.